Steam Path - Consulting Services

Equipment For Sale

Steampath Equipment
We have the connections and experience to find and source used Turbine-Generator, Mechanical Drive Turbine, or Compressors that meets your needs, or we will find someone who can find it for you!

Source Used and Reconditioned

- Power Plant Packages.
- Elliot YR Series Turbine, reconditioned.
- Air Compressors.
- Hoffman Blowers.
- Any small steam turbines (up to 3000HP).
- Solar Turbines.

Supply New
- New Gimpel Valves.
- New Prime Turbines up to 200 HP.

 

New Manufactured Buffalo Steam Turbine Generator Sets.

PDF: Buffalo Turbines Brochure

Turbine Generator sets can be 50 & 60 cycle.

Turbines can be condensing, extraction and back pressure.

Steam Path Services Inc. can provide technical direction on installation and service.

Requiring further information contact Dave Graham  e-mail dgraham@steampath.ca

Rogers TG-1 & 2

Posted by on Aug 29, 2017 in Equipment | 0 comments

Rogers TG-1 & 2

  Turbine Generator 1000 KW 1563 KVA 1200 KW max 2300 volts 470 PSIG 393 amps 650 F 80% PF 30 PSIG Exh. 30 3600 RPM 60n S/N 5A2295-1(&-2) 3600 RPM 120 Exc amps 125 Exc volts S/N 1526P55...

read more

G.E. Steam Turbine Model # 7TDYR 125R137

Posted by on Jan 13, 2017 in Equipment | 0 comments

G.E. Steam Turbine Model # 7TDYR 125R137 HP 400 RPM 3600 Inlet Steam Pressure 400psig Inlet Temperature 500 F Exhaust Pressure 65 psig   Some spares available, including spare rotor. Will rebuild turbine as new.

read more

G.E. Steam Turbine Model # 7TDRY 125R136

Posted by on Jan 13, 2017 in Equipment | 0 comments

G.E. Steam Turbine Model # 7TDRY 125R136 HP 1190 RPM 3990 Inlet Steam Pressure 400 psig Inlet Temperature 500 F Exhaust Pressure 65 psig   Some spares available, including spare rotor. Will rebuild turbine as new.  

read more

1007 KW, 60 Hz, Elliott steam turbine generator set with Elliott turbines, Model BYRH-UG

Posted by on Jan 5, 2017 in Equipment | 0 comments

1007 KW, 60 Hz,  Elliott steam turbine generator set with Elliott turbines, Model BYRH-UG, Serial number B1002145-C 1,  Single stage back pressure style units.  Engine, gearbox and generator are mounted in a common skid. The Elliott gearbox reduces the turbine speed of 5750 RPM to a final speed of 1800 RPM to drive a conventional 4-pole, 2-bearing alternator rated 1000kW/1176kVA with 0.85 PF, 163 Amps and wound for 2400/4160V/3/60 Hz service. Rated Power – 1350HP/1007kW; Rated Turbine Speed – 5750 RPM; Rated Inlet Steam Pressure...

read more

GE TURBINE – MODEL 7TDRY125R136

Posted by on Dec 11, 2015 in Equipment | 0 comments

(1) GE TURBINE MODEL 7TDRY125R136 HP 1190 RPM 3990 INLET PRESS 400PSIG INLET TEMP 500 FTT EXHAUST PRESS 65 PSIG AS IS WHERE IS Can BE REBUILT SOME SPARE PARTS CONTACT DAVE GRAHAM OR LEE (1) GE TURBINE MODEL 7TDRY 125 R138 HP 458 RPM 3800 INLET PRESS 400 PSIG INLET TEMP 550 FTT EXHAUST PRESS 70PSIG AS IS WHERE IS CAN BE REBUILT SOME SPARE PARTS CONTACT DAVE GRAHAM OR LEE

read more

BWC Generator

Posted by on Jan 13, 2015 in Equipment | 0 comments

The turbine has been totally disassembled and all parts replaced with new or reconditioned to like new standards. Rotor has been magna-fluxed, polished, and Balanced. Turbine case has been sandblasted, magna-fluxed, all sealing surfaces have been either machined or polished and resealed and assembled with new hardware. Nozzle block was ground and polished for better steam flow. Hand valve was reconditioned with new valve stem and the pneumatic cylinder for automatic control replaced. Turbine was reassembled with new journal and thrust...

read more

10 MW Biogas to Steam Cogeneration Plant

Posted by on Aug 14, 2014 in Equipment | 0 comments

10 MW Biogas-fired power plant. This complete cogeneration plant is capable of converting methane, landfill gas, biogas, or natural gas into electricity. Perfect for any site that has a supply of gas that needs to be converted to electric power. The plant includes a gas fired boiler, condensing steam turbine, electric generator and condenser. Currently, the entire plant is stored in a warehouse and is packaged for immediate shipment. 125,000 Lbs/Hr Deltak boiler 101,000 Lbs/Hr Terry condensing steam turbine 10 MW Ideal Electrics...

read more

4,885 HP (3758 KW) Siemens back pressure steam turbine

Posted by on Sep 25, 2012 in Equipment | 0 comments

UNUSED 4,885 HP (3758 KW) Siemens back pressure steam turbine. axial flow design, serial # 5833, Type G-300-2. turbine design speed 6883 rpm, driven machine speed 6883 rpm, turbine speed range 5930-7786 rpm, tripping speed 8565 rpm, main design steam pressure 39.7 bar @ 385 deg C, permissable deviation to 3* 40.7 bar 390 deg C, permissable deviation to 5* 42.74 bar, design pressure at exhaust flange 13.3 bar (may rise to 15.2 bar, may fall to 12.5 bar), Steam consumption 66.8 ton/hr @ 4885 HP. Stock Number...

read more

1495 kW KKK Ltd Back Pressure Turbine Generator, 1530 kW max

Posted by on Mar 12, 2012 in Equipment | 0 comments

Serial # 4555.002 Model CFR 5G5 Integrally geared high efficiency single stage design 29 tonne/hr (max) live steam @ 23 kg/cm2g and 340 deg C Exhausting back pressure 5.6 to 8.5 kg/cm2g @ 226 to 257 deg C 282 to 1495 kW output Assumed generator efficiency 89.6 to 95.3% Mech output 315 to 1569 kW Turbine speed 10740 rpm, coupling speed 1500 rpm

read more

3000 KW, 3750 KVA, Steam Turbine Generator

Posted by on Mar 12, 2012 in Equipment | 0 comments

This consists of: (1) steam turbine mfd by WH Allen and Sons, SN T4/7284(7), 4500 HP, speed 10250 rpm, gearbox speed 1500 rpm. Inlet pressure 635 psi @ 670 deg F, exhaust pressure 100 psi. (1) generator mfd by Bruce Peebles, SN 94359, 1500 rpm, 11000 volt, 50 Hz, Type ‘B’ insulation. (1) exciter generator, mfd by Westinghouse, 17.6 KW, 18.5 KVA, 1500 rpm, 3 phase, 50 Hz, 30.5 volt. (1) oil cooler (1) oil filter (1) gland condenser (1) combined stop & emergency valve (1) control panel

read more